Test Structure, Customer View – Hierarchy of Object Levels in the SECUTEST PRO and the SECULIFE ST BASE(25)
or in Devices with Database Extension, Feature KB01, “Z853R – SECUTEST DB+”
Figure 6 Database Structure as Customer View in Test Instruments with Feature KB01, “Z853R – SECUTEST DB+”
Note
Grayed Out Database Elements
The corresponding elements are grayed out in devices
without enabling for the following options: “Extended
database structure” Z835R (feature KB01 = property,
building, floor, room) and SECUTEST DB comfort Z853S
or feature KD01 (medical electric devices).
Note
Mandatory Fields
Mandatory fields are marked in red in the entry fields at
the test instrument, as well as in Figure 5 and Figure 6.
Note
Hierarchies
It’s imperative to adhere to the following hierarchies:
Room or Floor must always be subordinate to a Building.
Devices or ME Devices (medical electric devices) always be
allocated to a Customer.
Hierarchies and Data Migration
Database objects “Device” and “ME Device” must always be sub-
ordinate to a Customer. If so-called “legacy data” have been
imported into the test instrument which do not comply with this
rule (e.g. as a result of a firmware update or via the “Restore data-
base” function), Customer objects are generated automatically.
The same applies to database objects “Room” and “Floor”, which
must always be subordinate to a Building. In this case, Building
objects are generated automatically if necessary.
5.2.4 Switching Between 2 Tree Structure Views
(for SECUTEST PRO and SECULIFE ST BASE(25) or for devices
with feature KB01, “Z853R – SECUTEST DB+”)
The display can be switched back and forth between the lo-
cation and customer views by repeatedly pressing the MEM
key.
The database view can be exited by pressing the ESC key.
Customer
ID
Designation
Street
Device
ZIP code
City
Database
Manual
ID
Designation
Measurement 1
Measurement 2
Measurement 3
sequence
* Test interval: additionally available for test instruments with database extension, feature KB01, “Z853R – SECUTEST DB+” or feature KD01, “Z853S – SECUTEST DB
COMFORT”
** Only with SECUTEST PRO BT comfort or with database extension, feature KD01, “Z853S –
SECUTEST DB COMFORT”:
additional entry option for medical device (ME Device) and further parameters such as UDI and application parts
ME device **
UDI = unique device identification
1/6 2/6 3/6 4/6 5/6 6/6
ID Test interval * Comment No. of type B appl.
parts **
Cost center
Mains connection **
Designation Type Serial no. No. of type BF appl.
parts **
Department
Location Manufacturer Protection cate-
gory
No. of type CF appl.
parts **
UDI **
Customer
Customer
Customer MEM

Table of Contents

Other manuals for Gossen MetraWatt SECUTEST PRO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gossen MetraWatt SECUTEST PRO and is the answer not in the manual?

Gossen MetraWatt SECUTEST PRO Specifications

General IconGeneral
BrandGossen MetraWatt
ModelSECUTEST PRO
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals