Troubleshooting
58 333587B
DD3_
DD4_
Pump Alarm or
Deviation
(user
selectable)
Pump Diving P_ Pump diving
detected
Flow to pump inlet
restricted
Check inlet valve is open or check inlet
supply system for clogs.
DKC_ Pump Alarm Crossover Error
P_
Crossover error
in tandem
system
Second pump is in
error state when
crossover takes
place
Clear the error on the second pump.
EUD_ Driver Advisory Auto
Depressurization
Occurred
The pump has
auto
depressurized
The pump was auto
depressurized due
to the fact that the
pump did not move
for the auto
depressurize timer
Remember to primary/purge system before
running production.
EUH_ AMZ Record
Only
Heat Idle
Timeout
Automatically
turns off heat
after the pump
has not moved
for the
designated
amount of time
All zones on heat
module were
successfully turned
off
No action necessary.
EAUX ADM Advisory Download to
USB In Process
Information is
currently being
downloaded to
USB
Download to USB
initiated
No action necessary. Self-clearing.
EAW_ AMZ Record
Only
Heat_ Module
Warming Up
All zones on
heat module
are in warming
up state
All zones on heat
module were
successfully placed
into warm up
No action necessary.
EBUX ADM Advisory Download to
USB Complete
Download to
USB is
complete
All requested
information has
finished
downloading to
USB
No action necessary. Self-clearing.
EBH_ AMZ Record
Only
Heat_ Module Off All zones on
heat module
are turn off
All zones on heat
module were
successfully turned
off
No action necessary.
EC0X ADM Record
Only
Setup Values
Changed
A setting in the
setup screen
was changed
A setting in the
setup screens was
changed
No action necessary if changes were
desired.
EDF_ AMZ Record
Only
Heat_ Module
Placed into Heat
Soak
All zones on
heat module
are in heat soak
state
All zones on heat
module were
successfully placed
into heat soak
No action necessary.
EDS_ AMZ Record
Only
Heat_ Module
Placed into
Setback
All zone on
heat module
are in setback
state
All zones on heat
module were
successfully placed
into setback
No action necessary.
EDT_ AMZ Record
Only
Heat_ Module is
at desired
temperature
All zone on
heat module
are at desired
temperature
All zones on heat
module have
successfully
reached the desired
temperature
No action necessary if the desired
temperature was reached.
Error Location Type Error Name
Error
Description
Cause Solution