Appendix C - Communications Gateway Module (CGM) Connection Details
3A2098S 137
Inputs to PLC; Outputs from Graco PCF
For Basic Gateway Map 16T061
Outputs from PLC; Inputs to Graco PCF
For Basic Gateway Map 16T061
Signal Data Type BIT BYTE
FP1 - Dispenser Ready Boolean 0 0
FP1 - Dispenser No Alarm Boolean 1
FP1 - Dispense No Error Boolean 2
FP1 - Dispense in Process Boolean 3
FP1 - Dispense Volume OK Boolean 4
(Spare) Boolean 5
FP1 - Dispenser Purge
Requested
Boolean 6
FP1 - Dispenser Remote
Start / Purge in Process
Boolean 7
FP1 - Pressure Units - Bit 0 Boolean 0 1
FP1 - Pressure Units - Bit 1 Boolean 1
FP1 - Heartbeat Boolean 2
FP1 - Error Integer 0-7 2
FP2 - Dispenser Ready Boolean 0 3
FP2 - Dispenser No Alarm Boolean 1
FP2 - Dispense No Error Boolean 2
FP2 - Dispense in Process Boolean 3
FP2 - Dispense Volume OK Boolean 4
(Spare) Boolean 5
FP2 - Dispenser Purge
Requested
Boolean 6
FP2 - Dispenser Remote
Start / Purge in Process
Boolean 7
FP2 - Pressure Units - Bit 0 Boolean 0 4
FP2 - Pressure Units - Bit 1 Boolean 1
FP2 - Heartbeat Boolean 2
(Spare) Boolean 3-7
FP2 - Error Integer 0-7 5
Signal Data Type BIT BYTE
FP1 - Style Strobe Boolean 0 0
FP1 - Dispense Complete Boolean 1
FP1 - Dispense Gun 1 On Boolean 2
FP1 - Dispense Gun 2 On Boolean 3
FP1 - Dispense Gun 3 On Boolean 4
FP1 - Dispense Gun 4 On Boolean 5
FP1 - Error Reset Boolean 6
FP1 - Remote Start / Purge Boolean 7
FP1 - Style Integer 0-7 1
FP1 - Dispense Valve 1
Precharge on
Boolean 0 2
FP1 - Dispense Valve 2
Precharge on
Boolean 1
FP1 - Dispense Valve 3
Precharge on
Boolean 2
FP1 - Dispense Valve 4
Precharge on
Boolean 3
(Spare) Boolean 4-7
FP1 - Flow Command
Voltage
Integer 0-11 3-4
(Spare) Boolean 12-15
FP2 - Style Strobe Boolean 0 5
FP2 - Dispense Complete Boolean 1
FP2 - Dispense Valve 1 On Boolean 2
FP2 - Dispense Valve 2 On Boolean 3
FP2 - Dispense Valve 3 On Boolean 4
FP2 - Dispense Valve 4 On Boolean 5
FP2 - Error Reset Boolean 6
FP2 - Remote Start / Purge Boolean 7
FP2 - Style Integer 0-7
FP1 - Dispense Valve 1 Pre-
charge on
Boolean 0 7
FP1 - Dispense Valve 2 Pre-
charge on
Boolean 1
FP1 - Dispense Valve 3 Pre-
charge on
Boolean 2
FP1 - Dispense Valve 4 Pre-
charge on
Boolean 3
(Spare) Boolean 4-7
FP2 Command Voltage Integer 0-11 8-9
(Spare) Boolean 12-15