Appendix C - Communications Gateway Module (CGM) Connection Details
140 3A2098S
0x007 Software Part
Number
STR_15_12 Read Only
0x008 Software Ver-
sion
Version Read Only
0x0DD Maintenance
Units Type
Maintenance Units
Enumeration
Read Only
0x0DF Enabled Styles ### Read Only
0x203 Purge Period #### (minutes) Read /
Write
0x204 Dispense Trig-
ger Source
Dispense Trigger
Source Enumeration
Read /
Write
0x208 Command
Value Source
Command Value
Source Enumeration
Read /
Write
0x20F Bead Scale ### (percent) Read /
Write
0x210 Job End Mode Job End Mode Enu-
meration
Read /
Write
0x211 Job End Delay
Time
Integer (Seconds) Read /
Write
0x2B5 End Job On
Alarm
Boolean
0x212 Valve 1 Enable Boolean Read /
Write
0x213 Valve 2 Enable Boolean Read /
Write
0x214 Valve 3 Enable Boolean Read /
Write
0x215 Valve 4 Enable Boolean Read /
Write
0x216 Regulator On
Delay
### (mS) Read /
Write
0x217 Regulator Off
Delay
### (mS) Read /
Write
0x218 Valve 1 On
Delay
### (mS) Read /
Write
0x219 Valve 2 On
Delay
### (mS) Read /
Write
0x21A Valve 3 On
Delay
### (mS) Read /
Write
0x21B Valve 4 On
Delay
### (mS) Read /
Write
0x21C Valve 1 Off
Delay
### (mS) Read /
Write
0x21D Valve 2 Off
Delay
### (mS) Read /
Write
0x21E Valve 3 Off
Delay
### (mS) Read /
Write
0x21F Valve 4 Off
Delay
### (mS) Read /
Write
0x230 Flow Meter
Type
Flow Meter Type Enu-
meration
Read /
Write
Output
Bits
256-267 Description
Units
*See
Units
Definitions, page 145
Read or
Write
0x231 Flow Meter
K-Factor
##### (pulses/Liter,
pulses/kg)
Read /
Write
0x23C Outlet Pres-
sure Sensor
User Offset
sint32; #### (psi);
###.# (bar); ##.##
(Mpa)
Read /
Write
0x23D Inlet Pressure
Sensor User
Offset
sint32; #### (psi);
###.# (bar); ##.##
(Mpa)
Read /
Write
0x241 Maximum Out-
let Pressure
uint32; #### (psi);
###.# (bar); ##.##
(Mpa)
Read /
Write
0x244 Minimum Inlet
Pressure
uint32; #### (psi);
###.# (bar); ##.##
(Mpa)
Read /
Write
0x245 Maximum Inlet
Pressure
uint32; #### (psi);
###.# (bar); ##.##
(Mpa)
Read /
Write
0x248 Pressure Kp ####.## Read /
Write
0x249 Pressure Ki ####.## Read /
Write
0x247 Pressure Kd ####.## Read /
Write
0x254 Bead Kp ####.## Read /
Write
0x255 Bead Ki ####.## Read /
Write
0x260 Regulator Time
Advisory Limit
###### (hours) Read /
Write
0x262 Regulator Vol-
ume/Mass
Advisory Limit
Volume: ######
(gal(US)); ######
(gal(Uk)); ######
(Liters); Mass: ######
(lb), ###### (kg)
Read /
Write
0x264 Flow meter
Time Advisory
Limit
###### (hours) Read /
Write
0x266 Flow meter
Volume/Mass
Advisory Limit
Volume: ######
(gal(US)); ######
(gal(Uk)); ######
(Liters); Mass: ######
(lb), ###### (kg)
Read /
Write
0x268 Supply Time
Advisory Limit
###### (hours) Read /
Write
0x26A Supply Vol-
ume/Mass
Advisory Limit
Volume: ######
(gal(US)); ######
(gal(Uk)); ######
(Liters); Mass: ######
(lb), ###### (kg)
Read /
Write
0x26C V/P Time Advi-
sory Limit
###### (hours) Read /
Write
Output
Bits
256-267 Description
Units
*See Units
Definitions, page 145
Read or
Write

Table of Contents