Errors
3A2098S 73
B30_
B40_
31 High Material Material dispensed
during last dispense
cycle was above
amount requested plus
the allowed tolerance
Alarm or
Deviation
(user select-
able)
PCF regulator is not
regulating correctly
Check regulator and
repair if necessary
Incorrect style target
volume or tolerance
Enter correct values or
set tolerance to 0% to
disable error
B10_
B20_
32 Low Material Material dispensed
during last dispense
cycle below amount
requested minus the
allowed tolerance
Alarm or
Deviation
(user select-
able)
Partially plugged tip or
supply system
Clean tip and/or supply
system
Insufficient flow to
PCF regulator inlet
Increase flow rate to
regulator inlet
PCF regulator is not
regulating correctly
Check regulator;
repair if necessary
Incorrect style target
volume or tolerance
setting
B1C_
B2C_
33 Low Computed
Target
Requested volume/
mass differs from
entered process target
by more than entered
tolerance for style
requested
Alarm or
Deviation
(user select-
able)
Entered process target
incorrectly
Enter correct process
target
Entered tolerance
incorrectly
Enter correct tolerance
Requested volume
incorrectly
Check automation pro-
gram
Automation problem Verify automation is
correct
B3C_
B4C_
34 High Computed
Target
Requested volume/
mass differs from
entered process target
by more than entered
tolerance for style
requested
Alarm or
Deviation
(user select-
able)
Entered process target
incorrectly
Enter correct process
target
Entered tolerance
incorrectly
Enter correct tolerance
Requested volume
incorrectly
Check automation pro-
gram
Automation problem Verify automation is
correct
WND_ 51 Fluid Plate Key
Token Error
Missing or invalid key
token
Alarm FCM key token is
required to run system
Verify FCM key token
is installed
Verify FCM key token
is correct part number
P6D_ 52 Outlet Pressure
Transducer Error
Outlet pressure trans-
ducer error
Alarm Problem detected with
outlet pressure trans-
ducer
Verify outlet pressure
transducer is installed
and/or connected cor-
rectly
Replace if necessary
P6F_ 53 Inlet Pressure
Transducer Error
Inlet pressure trans-
ducer error
Advisory Problem detected with
inlet pressure trans-
ducer
Verify inlet pressure
transducer is installed
and/or connected cor-
rectly
Replace if necessary
F6D_ 54 Flow Meter Error Flow Meter error Alarm Problem detected with
flow meter
Verify flow meter is
installed and/or con-
nected correctly
Replace if necessary
Event
Code
Gateway
Error No. Event Name
Event
Description Event Type Cause Solution
Fluid Plate Events and Errors