EasyManua.ls Logo

GRAPHTEC FC5100-100 - Error Messages in HP-GL Command Mode

GRAPHTEC FC5100-100
201 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Test Modes and Troubleshooting: Error Messages
139
Set the plotter’s interface conditions to match the software’s interface condi-
tions.
Table 10: Error Messages in HP-GL Command Mode
Symptom Cause Solution
An unrecognizable instruction was exe-
cuted.
Execute a recognizable command.
A command was executed with the wrong
number of parameters.
Execute the command with the correct
number or parameters.
A command containing an unusable
parameter was specified.
Execute the command with parameters
specified within their permissible ranges.
An unrecognizable instruction was exe-
cuted.
Specify a recognizable command.
A command was executed with coordi-
nated data that exceeds the effective cut-
ting/plotting area.
Execute the command with its coordinate
data specified within the effective cutting/
plotting area.
The data being input exceeds the capacity
of the plotter’s downloadable character
buffer, polygon buffer, etc.
Increase buffer size.
During the execution of an output com-
mand, another output command was exe-
cuted.
Check the flow of your programmed data.
ERROR 1
NOT RECOGNIZED
ERROR 2 WRONG NUMBER
OF PARAMETERS
ERROR 3 OUT OF RANGE
PARAMETERS
ERROR 5 UNKNOWN
CHARACTER SET
ERROR 6
PARAMETER OVERFLOW
ERROR 7
BUFFER OVERFLOW
ERROR 10 INVALID
I/O OUTPUT REQUEST

Table of Contents