Advanced Functions and Settings: AXIS ALIGNMENT - Axis Alignment Parameter Setting
90
between point 1 and point 2. The measured distance is shown on the 3
rd
row. Set
the actual distance on the 4
th
row.
• Press the RIGHT or LEFT ARROW key to move the cursor.
• Press the UP or DOWN key to increase or decrease the number for the distance
value.
• Press the ENTER key to store the setting.
The following menu appears:
Use the POSITION key to change the distance value to that of the printed
image, i.e., the distance between point 1 and point 3.
• Press the RIGHT or LEFT ARROW key to move the cursor.
• Press the UP or DOWN key to increase or decrease the number for the distance
value.
• Press the ENTER key to store the setting.
The following menu appears:
The light pointer or the loupe move back to the Axis Point 1.
If the Axis Point 1 is not the origin point of the pre-printed image, press the
POSITION key to move the light pointer or the loupe to the desired origin point for
cutting.
If the Axis Point 1 is the origin point of the pre-printed image, press the ENTER
key. Then press the ENTER key to store the setting. The READY menu appears,
the plotter is ready to start the cutting operation.
DISTANCE
POINT 1-3
00399.6 mm.
OK?.......... 00400.0 mm.
AXIS ORIGIN POINT
.
X= ... mm
Y= ....mm
CONDITION 1.........14.
30.
READY.............4.
CB09Ux...0.