FC8600-UM-251-9370 3-4
3 OPERATIONS
Icon of the corresponding operation button is displayed in the screen to change the setting values.
Increase or decrease the setting
value using POSITION (pq) key.
Select the change unit by [FAST]
key.
Select the setting by
number keys (1, 2, 3, 4) or
POSITION (pqtu) keys.
Example of screen to change the settings value
Contents of Operation from Menu Screen
MENU screen
Contents of the operation and settings that is displayed in MENU screen with [MENU] key is as following:
[1] (TOOL): ...... Make the setting for the operation of the tool.
[2] (ARMS): ...... Make the settings and operation to position the tool and media, such as automatic scanning
of the registration marks by the ARMS.
[3] (AREA): ...... Make the settings for area, magnification, rotation, reverse, etc., of the cutting.
[4] (MEDIA): .... Make the setting of the condition for the media.
[p] (I/F): .......... Make the settings of the condition for the interfacing with the control computer.
[q] (ADV): ....... Make the settings of the conditions for the basic operation of the plotter, such as display
language, unit of the measurements, sensor, etc.
[t] (TEST): ...... Does the operation necessary for maintenance, such as self diagnostic test or printout of the
condition settings list.
MENU: ............. It will close the MENU screen and return to default screen.
Contents of Operation from CONDITION Key
CONDITION screen (1-3)
Tool conditions are set in the setting screens displayed by the [CONDITION] key.
Up to 8 CONDITION settings can be saved with different settings in numbers 1 through 8.
CONDITION: It will clear the CONDITION screen and return to default screen.