7. Monitor progress as indicated by both the Status and Details column. When finished,
the Status column indicates complete.
Related Links
Upgrade software on SAN K2 clients on page 41
Power cycle K2 system on page 55
Power cycle K2 system
Do not do this task if:
• The standard, SiteConfig-supported Restart operation is sufficient for the required
restart after installing software.
Do this task if:
• You must power cycle, rather than restart, the K2 system after installing software.
When you must shutdown and then power up (power cycle) a device, rather than restart
the device, you must use a combination of SiteConfig and manual operations.
1. In the SiteConfig tree-view, right-click the device and select Shutdown.
SiteConfig initiates the Windows shutdown operation on the device and the
device powers off.
2. At the local device, verify that shutdown operations are complete, then press the
standby button or otherwise manually power up the device.
The device starts up.
3. Verify that startup operations are complete on the device.
4. In SiteConfig, in the tree-view, right-click the device and select Set Restart
Complete.
This re-synchronizes SiteConfig regarding the current state of the device. If
software deployment tasks were waiting for the restart to occur, SiteConfig now
allows them to proceed.
Install required Windows update
Do not do this task if one of the following is true:
• A K2 Summit Production Client or K2 Solo Media Server installed new with K2
software version 7.1.x or higher, in which case the required Windows update version
2.0.50727.4022 is pre-installed.
• A K2 Summit Production Client or K2 Solo Media Server already upgraded to the
required Windows update version 2.0.50727.4022.
Do this task if:
• A K2 Summit Production Client or K2 Solo Media Server with Windows update
at a version lower than 2.0.50727.4022.
12 May 2010 K2 Version 7.2.7 Release Notes & Upgrade Instructions 55
Upgrading K2 systems