Model 672/675 Technical Reference Manual
3-13
Setup
This menu was designed for accessing the items that will need to be changed the most often. Below is an
explanation of the choices in the menu. Follow the instructions on the display for each key.
F
UNCTION
K
EY
P
ARAMETER
D
ESCRIPTION
D
EFAULT
S
ETTING
K
EYPRESSES
CHANGE
SAMPLE
Change the default
sample size
10
Key in new sample size and press [Enter] to
accept or [F5] to escape
CLEAR TOTALS
Clears the
accumulation
registers
Not applicable Press [Enter] to clear totals or [Clr] to escape
KEY-IN APW
Key in an average
piece weight for
sample
0
Key in new average piece weight and press
[Enter] or [F5] to escape
SETUP MENUS
Continues on to the
Setup Menus
Not applicable Press [F4] to continue
Setup Menus
This is the next level of menus, which offer more advanced setup.
F
UNCTION
K
EY
P
ARAMETER
D
ESCRIPTION
D
EFAULT
S
ETTING
K
EYPRESSES
CAL
Calibration any of the
enabled scales
Not applicable
Key in access code and press Enter or press
[F5] to escape
DISPLAY STYLE
Chose how the
display will appear
Style 2
Press either [F1] – [F3] to chose the desired
display style or [F5] to escape
PRINT MENU
Choose what
information to print
out
Not applicable Continues on to the Print Menu selections
ADVANCE
SETUP
Continues on to the
Advanced Setup
Menu
Not applicable See page 3-20
Cal (Calibration)
Refer to Chapter 5 for complete instructions on calibrating the Model 675.
Display Style
Choose one of the display types and press [F5] (EXIT) to save the change and return to the main menu.
Style 1
This is the classic GSE 2x5 display. The weight or quantity will be displayed in larger font while the prompts
will be to the right of the weight display.
Style 2
This style incorporates the classic GSE 2x5 display along with two smaller displays, which will show other
parameters. Press the [SELECT] key from the QUICK COUNT to toggle through the different parameter
choices.
Preset Print Formats
The preset print formats are viewable on the LCD display. Use the [F3] left arrow and [F4] right arrow keys
to view all transmit styles. Chose the desired format by viewing it on the screen. Press the [F5] (EXIT) key to
save the format and return to the main menu.