ASR-2000 Series User Manual
144
AC/DC Voltage
Range
(ACV/DCV)
There are 2 voltage range settings: HI
200V & LO 100V, which result in
varied ranges of ACV and DCV
values, respectively.
Fset
(Frequency)
Sets the frequency of the step. There
are 3 secondary frequency settings
that determine how the frequency is
output.
CT: Sets the frequency level of the
step immediately to Fset values.
KP: Sets the frequency level to “keep”
the frequency of the previous step.
SP: Linearly increases or decreases
the frequency from the end of the
previous step to the end of the
current step.
It is available for AC+DC-INT and AC-INT modes only.
Wave
Sets the outputting waveform of the
step. Up to 4 waves including sine,
square, triangle and arbitrary (1-16)
wave shapes are available.
It is available for AC+DC-INT and AC-INT modes only.
Jump To
The Jump To setting determines
which step to jump to at the end of
the step. If Jump To is turned off, the
unit will follow the Term (Step
termination) setting for the step.
Jump Cnt
Determines the number of times to
loop the jump step.

Table of Contents

Other manuals for GW Instek ASR-2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek ASR-2000 Series and is the answer not in the manual?

GW Instek ASR-2000 Series Specifications

General IconGeneral
BrandGW Instek
ModelASR-2000 Series
CategoryPortable Generator
LanguageEnglish

Related product manuals