ASR-2000 Series User Manual
208
Output rating for DC mode
-250.0 V to +250.0 V / -500.0 V to +500.0 V
±(|0.5 % of set| + 0.6 V / 1.2 V)
For an output voltage of -250 V to -25 V, +25 V to +250 V / -500 V to -50 V,
+50 V to +500 V, no load, AC voltage setting 0V (AC+DC mode) and 23°C ±
5°C
For an output voltage of 1.4 V to 100 V / 2.8 V to 200 V. Limited by the power
capacity when the output voltage is 100 V to 250 V / 200 V to 500 V.
Within 5 ms, Limited by the maximum current.
±0.15% @45 - 65Hz
±0.5% @DC, all other frequencies
(0 to 100%, via output terminal)
0.7 Vrms / 1.4 Vrms (TYP)
Power source input voltage is 100 V, 120 V, or 230 V, no load, rated output.
For an output voltage of 75 V to 175 V / 150 V to 350 V, a load power factor
of 1, stepwise change from an output current of 0 A to maximum current (or
its reverse), using the output terminal on the rear panel.
For 5 Hz to 1 MHz components in DC mode using the output terminal on the
rear panel.