MANU:DCW:ARCC 10
Sets the DCW ARC value to 10mA.
Sets or returns the IR voltage in kV. The test must
first be in IR mode before this command can be
used.
MANU:IR:VOLTage <NR2>
MANU:IR:VOLTage?
Parameter/
Return parameter
0.05 ~ 1 (0.05kV to 1kV: steps of .05)
*GPT-99XX/99XXA also includes a
0.125kV point.
MANU:IR:VOLT 1
Sets the IR voltage to 1 kV.
Sets or returns the IR HI SET resistance value in
MΩ (GPT-98XX) or GΩ. The test must first be in IR
mode before this command can be used.
MANU:IR:RHISet <NR1>|NULL
MANU:IR:RHISet?
Parameter/
Return parameter
GPT-98XX only:
2 ~ 9999 (unit = MΩ)
GPT-99XX/GPT-99XXA only:
Format A: 0.002 ~ 50.00 (unit = GΩ)
Format B: 0.002G ~ 50.00G
Format C: 2M ~ 50000M
Sets the HI SET value to ∞.
MANU:IR:RHIS 10
Sets the IR HI SET resistance to 10 MΩ.