PEL-3000(H) User Manual
76
Display
0.000
V
0.0000
A
0.00
W
Level1 0.00
LOADRS232
01/Oct/2017
W
0:00:05
Elapsed time
Cut Off Time
Description
The Cut Off Time function will turn the load off
after a set-amount of time. After the load has been
turned off, a popup screen will display the voltage
level when the load was turned off.
Operation
1. Press
Main
> Configure[F5] > Other[F2] and
set the Cut Off Time.
Range:
OFF, 1 second - 999 hours:59
minutes:59 seconds
Display
Mode
CP
I Range
H 8.75A
V Range
L 80V
Function
Dynamic
Configure
0.000
V
0.0000
A
0.00
W
Timer1 0.025
Level2 0.00
Level1 0.00
LOADRS232
Fine
01/Oct/2018
mS
W
W
0:00:05
Cut off time
Time Up
Voltage : 5.1223V
Enter
Voltage at cut off time