REMOTE CONTROL
35
ON
Turns blink ON
Return parameter 0
<NR1>Turns blink OFF
1
<NR1>Turns blink ON
Example DISP:BLIN 1
Turns blink ON.
Initiate Commands
INITiate[:IMMediate]:NAME .............................................35
INITiate[:IMMediate]:NAME
Set
Description
The INITiate command starts the TRANsient or
OUTPut trigger.
Syntax INITiate[:IMMediate]:NAME {TRANsient|OUTPut}
Parameter TRANSient
Starts the TRANsient trigger.
OUTPut
Starts the OUTPut trigger.
Example INITiate:NAME TRANient
Starts the TRANSient trigger.
Measure Commands
MEASure[:SCALar]:CURRent[:DC]...................................35
MEASure[:SCALar]:VOLTage[:DC] .................................. 36
MEASure[:SCALar]:POWer[:DC] ....................................... 36
MEASure[:SCALar]:CURRent[:DC]
Query
Description
Takes a measurement and returns the average
output current
Syntax MEASure[:SCALar]:CURRent[:DC]?
Return parameter <NRf>
Returns the current in amps.