EasyManuals Logo

GW Instek PSW Series Programming Manual

GW Instek PSW Series
87 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
REMOTE CONTROL
49
Syntax TRIGger:TRANsient[:IMMediate]
TRIGger:TRANsient:SOURce
Set
Query
Description
Sets or queries the trigger source for the transient
system.
Syntax
Query Syntax
TRIGger:TRANsient:SOURce {BUS | IMMediate}
TRIGger:TRANsient:SOURce?
Parameter/Return
BUS
Internal software trigger. Waits for the
*TRG (or IEEE 488.1 “get” group
execute trigger) command to start the
trigger.
IMMediate
Starts the trigger immediately.
(default)
Example TRIG:TRAN:SOUR BUS
Sets the trigger source as BUS.
TRIGger:OUTPut[:IMMediate]
Set
Description
Generates a software trigger for the output trigger
system.
Syntax TRIGger:OUTPut[:IMMediate]
TRIGger:OUTPut:SOURce
Set
Query
Description
Sets or queries the trigger source for the output
system.
Syntax TRIGger:OUTPut:SOURce {BUS | IMMediate |
EXTernal}
Query Syntax TRIGger:OUTPut:SOURce?
Parameter/Return
BUS
Internal software trigger. Waits for the
*TRG (or IEEE 488.1 “get” group
execute trigger) command to start the
trigger.
IMMediate
Starts the trigger immediately.
(default)

Table of Contents

Other manuals for GW Instek PSW Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek PSW Series and is the answer not in the manual?

GW Instek PSW Series Specifications

General IconGeneral
Ripple & Noise (CC)≤ 3mArms
ProtectionsOVP, OCP, OTP
Remote SenseYes
ProgrammableYes
Operating Temperature0°C to 40°C
Storage Temperature-20°C to 70°C
Voltage Resolution1mV
Current Resolution1mA
Current Accuracy±0.1% + 10mA
Ripple & Noise (CV)≤1mVrms
Load Regulation (CC)≤0.1% + 5mA
Line Regulation (CC)≤0.1% + 5mA
Remote InterfaceUSB, RS232
DisplayLCD