PSW Series User Manual 
52 
SYSTem:CONFigure:BLEeder:STATe 
Set
Query
 
Description 
Sets or queries the status of the bleeder resistor. 
Syntax 
Query Syntax 
SYSTem:CONFigure:BLEeder[:STATe] {OFF|ON|0|1} 
SYSTem:CONFigure:BLEeder[:STATe]? 
Parameter  0 
<NR1> Turns the bleeder resistor off. 
  OFF 
Turns the bleeder resistor off. 
  1 
<NR1> Turns the bleeder resistor on. 
  ON 
Turns the bleeder resistor on. 
Return parameter  <Boolean>
Returns bleeder resistor status. 
SYSTem:CONFigure:BTRip[:IMMediate] 
Set
 
Description 
Trips the power switch trip (circuit breaker) to 
turn the unit off (shut down the power). 
Syntax SYSTem:CONFigure:BTRip[:IMMediate] 
SYSTem:CONFigure:BTRip:PROTection 
Set
Query
 
Description 
Enables/Disables the power switch trip (circuit 
breaker) when the OVP or OCP protection settings 
are tripped. This setting only applies after power 
has been reset.  
Syntax SYSTem:CONFigure:BTRip:PROTection {OFF|ON|0|1} 
Query Syntax  SYSTem:CONFigure:BTRip:PROTection? 
Parameter 
0 
<NR1> Disables the power switch trip for 
OVP or OCP. 
  OFF 
Disables the power switch trip for OVP or 
OCP. 
  1 
<NR1> Enables the power switch trip for 
OVP or OCP. 
  ON 
Enables the power switch trip for OVP or 
OCP. 
Return parameter  <Boolean>
Returns power switch trip setting.