EasyManuals Logo

GW Instek PSW Series Programming Manual

GW Instek PSW Series
87 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #41 background imageLoading...
Page #41 background image
REMOTE CONTROL
41
STATus:QUEStionable:CONDition
Query
Description
Queries the status (bit sum) of the Questionable
Status register. This query will not clear the
register.
Query Syntax STATus:QUEStionable:CONDition?
Parameter <NRf>
0~32767
Return parameter <NR1>
0~32767
STATus:QUEStionable:ENABle
Set
Query
Description
Sets or queries the bit sum of the Questionable
Status Enable register.
Syntax
Query Syntax
STATus:QUEStionable:ENABle <NRf>
STATus:QUEStionable:ENABle?
Parameter <NRf>
0~32767
Return parameter <NR1>
0~32767
STATus:QUEStionable:PTRansition
Set
Query
Description
Sets or queries the bit sum of the positive
transition filter of the Questionable Status register.
Syntax
Return Syntax
STATus:QUEStionable:PTRansition <NRf>
STATus:QUEStionable:PTRansition?
Parameter <NRf>
0~32767
Return parameter <NR1>
0~32767
STATus:QUEStionable:NTRansition
Set
Query
Description
Sets or queries the negative transition filter of the
Questionable Status register.
Syntax
Query Syntax
STATus:QUEStionable:NTRansition <NRf>
STATus:QUEStionable:NTRansition?

Table of Contents

Other manuals for GW Instek PSW Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek PSW Series and is the answer not in the manual?

GW Instek PSW Series Specifications

General IconGeneral
Ripple & Noise (CC)≤ 3mArms
ProtectionsOVP, OCP, OTP
Remote SenseYes
ProgrammableYes
Operating Temperature0°C to 40°C
Storage Temperature-20°C to 70°C
Voltage Resolution1mV
Current Resolution1mA
Current Accuracy±0.1% + 10mA
Ripple & Noise (CV)≤1mVrms
Load Regulation (CC)≤0.1% + 5mA
Line Regulation (CC)≤0.1% + 5mA
Remote InterfaceUSB, RS232
DisplayLCD