APPENDIX
85
Rear panel USB State F-21 0 = Absent
Rear Panel USB Mode F-22 2 = USB CDC
GPIB address F-23 8
LAN setting
MAC Address-1 F-30 0x00~0xFF
MAC Address-2 F-31 0x00~0xFF
MAC Address-3 F-32 0x00~0xFF
MAC Address-4 F-33 0x00~0xFF
MAC Address-5 F-34 0x00~0xFF
MAC Address-6 F-35 0x00~0xFF
LAN F-36 1 = Enable
DHCP F-37 1 = Enable
IP Address-1 F-39 0
IP Address-2 F-40 0
IP Address-3 F-41 0
IP Address-4 F-42 0
Subnet Mask-1 F-43 0
Subnet Mask-2 F-44 0
Subnet Mask-3 F-45 0
Subnet Mask-4 F-46 0
Gateway-1 F-47 0
Gateway-2 F-48 0
Gateway-3 F-49 0
Gateway-4 F-50 0
DNS address -1 F-51 0
DNS address -2 F-52 0
DNS address-3 F-53 0
DNS address-4 F-54 0
Sockets active F-57 1 = Enable
Web Server active F-59 1 = Enable
Web password active F-60 1 = Enable
Web setting password F-61 0000
Power On Configuration
CV Control F-90 0= Panel control (local)
CC Control F-91 0= Panel control (local)
Power-ON Output F-92 0 = OFF at startup
Master/Slave F-93 0 = Master/Local
External Out Logic F-94 0= High ON
Power Switch trip F-95 1 = Disable
Calibration
Calibration F-00 0000

Table of Contents

Other manuals for GW Instek PSW Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek PSW Series and is the answer not in the manual?

GW Instek PSW Series Specifications

General IconGeneral
Ripple & Noise (CC)≤ 3mArms
ProtectionsOVP, OCP, OTP
Remote SenseYes
ProgrammableYes
Operating Temperature0°C to 40°C
Storage Temperature-20°C to 70°C
Voltage Resolution1mV
Current Resolution1mA
Current Accuracy±0.1% + 10mA
Ripple & Noise (CV)≤1mVrms
Load Regulation (CC)≤0.1% + 5mA
Line Regulation (CC)≤0.1% + 5mA
Remote InterfaceUSB, RS232
DisplayLCD