Hantek 6022BE
Measure
Select Channel
Maximum: Voltage of the absolute maximum level, Measured over the entire
waveform
Minimum: Voltage of the absolute minimum level, Measured over the entire
waveform
Peak To Peak: Peak-to-peak = Max Min, Measured over the entire
waveform
Top: Voltage of the statistical maximum level, Measured over the entire
waveform
Base: Voltage of the statistical minimum level, Measured over the entire
waveform
Middle: Voltage of the 50% level from base to top
RMS: The Root Mean Square voltage over the entire waveform
Amplitude: Amp = Base – Top, Measured over the entire waveform
Mean: The arithmetic mean over the entire waveform
Cycle Mean: The arithmetic mean over the first cycle in the waveform
41