9-5. Communication Interface
9-7. Storage Condition
9-8. Structure
9-6. Operating Environment
NP100
Standard
Communication address
Communication method
Synchronization
Communication sequence
Communication distance
Communication speed
Start bit
Data bit
Parity bit
Stop bit
Communication protocol
Response time
EIA RS485
31, 1~99 setting available
2 wire half duplex
Start-stop synchronous mode
None
1.2Km max.
600, 1200, 2400, 4800, 9600 BPS
1 BIT
7 or 8 BIT
None, even numbers, odd numbers
1 or 2 BIT
PC LINK
Reception treatment time + (Response time
10mS)
Installation environment
Normal operation
condition
Influence of ambient
temperature
Influence of voltage
regulation
Continuous vibration (5 ~ 14 Hz) : Forward width 1.2 mm max.
(4 ~ 150 Hz) : 4.9
(0.5 G) max.
Vibration : 14.7
(1.5 G), 15 sec. max. (each 3 direction)
Shock : 147
(15 G), 11msec max. (6 direction each 3 times)
Ambient temperature : 0 ~ 50
Ambient humidity : 35 ~ 85 % RH (no condensation)
Influence of magnetic : 400 AT/m max.
Warm-up time : 30 min. min.
T/C, Voltage input :
1 V/ or 0.01 %/ of F.S.
R.T.D input :
0.05 / max.
Analog output :
0.05 % / max. (continuous output)
Analog input :
V / 10 V or
Analog output : 0.05 % of F.S / 10 V max.
Storage temperature
Storage humidity
Shock
-25 ~ 70
5 ~ 95 % RH (no condensation)
1 m max. in packing condition
Material
Weight
Panel cutout
Plastic case
696 g (including brackets & box)
96(W)
96(H) 100(D)