It sets up the repeat frequency and set up items.
Signal
Setup range
Display
condition
Initial value
Setup group for
program repeat
frequency
0 : limitless frequency
/ 1~99
Always
1
8-2-1. Setup Group for Program Repeat Frequency
Repeat
frequency setup
Item
1)Set up of repeat frequency : It is an item the decides the number of repetition for the program
established in each pattern. It keeps repeating when “0” is set and the number could range from 1 to 99.
Setup group for program repeat frequency is indicated if the system is operated as follow when power
is ON.
Power
ON
2.5 sec
Setup group for program frequency will be indicated if operated as follow under the power ON
condition (operation indicator mode). However, if you do not operate the key for more than 30 seconds,
operation indicator mode will be displayed.
Power
ON
2.5
sec.