5 - Operation
5.7
Filling of main tank using Quick Fill (optional)
The main tank is filled using the Quick Fill as follows:
1. Turn bottom Suction Manifold valve to “Main Tank”.
2. Remove plug from Quick Fill coupler and connect filling hose
from water supply (i.e. overhead fill tank).
3. Turn water supply “On (so filling hose is pressurized).
4. Turn top Suction Manifold valve towards “Quick Fill” function.
5. Fill tank to desired level. Keep an eye on the level indicator.
6. Turn top Suction Manifold valve “Off to discontinue filling process.
7. Turn water supply “Off and remove the filling hose.
8. Replace Quick Fill plug.
The flush tank is filled using the Quick Fill as follows:
1. Turn bottom Suction Manifold valve to “Flush Tank”.
2. Remove plug from Quick Fill coupler and connect filling hose
from water supply (i.e. overhead fill tank).
3. Turn water supply “On (so filling hose is pressurized).
4. Turn top Suction Manifold valve towards “Quick Fill” function.
5. Fill tank to desired level. Be careful not to overfill.
6. Turn top Suction Manifold valve “Off to discontinue filling process.
7. Turn water supply “Off and remove the filling hose.
8. Replace Quick Fill plug.
Capacity: 66 gal. (250 liters).
Only fill flush tank with clean water! To avoid algae developing in
the flush tank, always drain the flush tank if the sprayer is not in
use for a longer period of time.
For cleaning purposes, etc. the flush tank is also accessible via the
tank lid on top of tank.
Filling of flush tank using Quick Fill (optional)
DANGER! Avoid contamination or personal injury. Do not turn suction valve to “Quick Fill” unless filling hose is con-
nected. If this valve is open when the pump is not engaged, liquid can flow out of the valve.
WARNING! Do not leave the sprayer while filling the tank. Keep an eye on the level indicator in order NOT to over-
fill the tank.
DANGER! Avoid contamination or personal injury. Do not turn suction valve to “Quick Fill” unless filling hose is con-
nected. If this valve is open when the pump is not engaged, liquid can flow out of the valve.
WARNING! Do not leave the sprayer while filling the tank. Keep an eye on the tank in order NOT to overfill.