8 - Technical specifications
8.3
Tire size Rec. inflation pressure in p.s.i. (bar)
Operating temperature range: 36°F to 104°F (2° to 40° C)
Operating pressure for safety valve: 220 psi (15 bar)
Max. pressure on the pressure manifold: 290 psi (20 bar)
Max. pressure on the suction manifold: 100 psi (7 bar)
12.4 x 24 25 (1.7)
11.2 x 38 35 (2.4)
Tire pressure
Filter gauze width
30 mesh: 0.58 mm
50 mesh: 0.30 mm
80 mesh: 0.18 mm
100 mesh: 0.15 mm
DANGER! Never inflate tires more than to the pressure specified in the table. Over-inflated tires can explode and
cause severe personal injuries! See the part “Occasional maintenance - Change of tire”.
Temperature and pressure ranges
Filters and nozzles
When the equipment has completed its working life, it must be thoroughly cleaned. The tank, hose and synthetic fittings
can be incinerated at an authorized disposal plant. The metallic parts can be scrapped. Always follow local legislation
regarding disposal.
Materials used:
Tank: HDPE
Hoses: PVC
Valves: mainly glass-filled PA.
Fittings: PA
Disposal of the sprayer
Materials and Recycling