Provides guidance on selecting a location, required clearances, and general electrical requirements for installation.
Details wall mounting procedures, including weight support and specific wall types, with critical safety warnings.
Covers piping requirements, support, isolation valves, unions, drain valves, and thread sealant for proper installation.
Provides detailed instructions and safety warnings for connecting the 120Vac power wiring to the ETS-LT assembly.
Explains the wiring connections for an optional High Temperature Limit Valve using a motorized ball valve.
Guides the user through the initial system startup menu screens for programming the ETS-LT control module.
Explains the different control modes and how to set display units (°F/°C).
Sets the desired mixed valve outlet temperature, with warnings for high temperatures.
Configures the high-temperature limit setpoint and delay to prevent excessive temperatures and false alarms.
Adjusts PID aggressiveness to control temperature fluctuations and improve setpoint stability.
Enables setting up temperature schedules with start times and temperatures for different periods and days.
Provides access to reset system lockouts after correcting the underlying conditions.
Step-by-step instructions for calibrating the actuator when assembled to the valve.
Instructions for removing, replacing, or upgrading the ETV Platinum Plus control module.
Provides guidance on selecting a location, required clearances, and general electrical requirements for installation.
Details wall mounting procedures, including weight support and specific wall types, with critical safety warnings.
Covers piping requirements, support, isolation valves, unions, drain valves, and thread sealant for proper installation.
Provides detailed instructions and safety warnings for connecting the 120Vac power wiring to the ETS-LT assembly.
Explains the wiring connections for an optional High Temperature Limit Valve using a motorized ball valve.
Guides the user through the initial system startup menu screens for programming the ETS-LT control module.
Explains the different control modes and how to set display units (°F/°C).
Sets the desired mixed valve outlet temperature, with warnings for high temperatures.
Configures the high-temperature limit setpoint and delay to prevent excessive temperatures and false alarms.
Adjusts PID aggressiveness to control temperature fluctuations and improve setpoint stability.
Enables setting up temperature schedules with start times and temperatures for different periods and days.
Provides access to reset system lockouts after correcting the underlying conditions.
Step-by-step instructions for calibrating the actuator when assembled to the valve.
Instructions for removing, replacing, or upgrading the ETV Platinum Plus control module.
| Input Voltage | 24 VAC |
|---|---|
| Enclosure Rating | NEMA 1 |
| Communication Protocol | Modbus RTU |
| Relay Outputs | 2 |
| Application | Heating control |
| Operating Temperature | 0° to 50°C |
| Humidity Range | 5% to 95% RH, non-condensing |