When cabling the charging system, follow all instruc-
tions in chapter1andproceedasfollows:
• Appropriatelypreparethemainsconnectingcable
(Ø10-20mm//max.5*6mm²)andconnectitas
shown in Fig.6 - no.1. The illustration shows the
mainsconnectionviathreephases.UseN,L1and
PE to connect the charging system to the mains via
onephase.
• Congurethemaximumchargingcurrentof6Ato
16AusingrotaryswitchS3,asshowninFig.6 - no.4.
0=6A(defaultsetting),1=8A,2=10A,3=12A,
4=14A,5...9=16A
• Optional:Preparethedatacables(DigitalIn(EN)
/DigitalOut(SW)andLAN)andconnectthemas
shown in Fig.6 - no.2and no.3 . Remove the cable
bridgebeforeconnectinganexternalblockingdevice
viaDigitalIn.
FitthestrainreliefasshowninFig.6 - no.5andxthe
datacablesusingcableties.Mountthelowercoverof
the charging system as shown in Fig.7.
Fig.7
max. 2 Nm
Fig.6
N
SW
S3
EN
L1 L3 PEL2
N
L1 L3 PEL2
max. 2.5 Nm
21
3
5
4
3 4 5 6 71 2
Cabling