Organization mode of operation | Parameters
9
HEIDENHAIN | MANUALplus 620 | User's Manual | 12/2017
621
Settings for fixed cycles and units
Departing/thread cutting, inside [ABGI] (602504): Departing strategy
1: XZ – Simultaneously
2: XZ – Sequentially
3: ZX – Sequentially
Thread run-in length [GAL] (602505)
[mm]: Default value for the run-in length B
Thread run-out length [GUL] (602506)
[mm]: Default value for the run-out length (ending length) P
Processing
Measuring (602600)
Measuring loop counter [MC] (602602)
Specifies the measuring intervals
Measuring departing length in Z [MLZ] (602603)
[mm]: Departing length in the Z direction
Measuring departing length in X [MLX] (602604)
[mm]: Departing length in the X direction
Measuring allowance [MA] (602605)
[mm]: Allowance on the element to be measured
Measuring cut length [MSL] (602606)
[mm]: Measuring cut length
Processing
Drilling (602700)
Approach/front face – drilling [ANBS] (602701): Approach strategy
1: XZ – Simultaneously
2: XZ – Sequentially
3: ZX – Sequentially
Approach/lateral surface – drilling [ANBM] (602702): Approach strategy
1: XZ – Simultaneously
2: XZ – Sequentially
3: ZX – Sequentially
Departing/front face – drilling [ABBS] (602703): Departing strategy
1: XZ – Simultaneously
2: XZ – Sequentially
3: ZX – Sequentially
Departing/lateral surface – drilling [ABBM] (602704): Departing strategy
1: XZ – Simultaneously