Manual Operation and Setup | Managing presets
13
532
HEIDENHAIN | TNC 320 | ISO Programming User's Manual | 10/2017
Operating notes:
Basic rotations from the preset table rotate the
coordinate system about the preset, which is shown
in the same row as the basic rotation.
When presetting, the positions of the tilting axes
must match the tilted situation.
If the Tilt working plane function is not active,
the position display for the rotary axes must be
= 0° (zero the rotary axes if necessary)
If the Tilt working plane function is active, the
position displays for the rotary axes must match
the angles entered in the 3-D ROT menu
PLANE RESET does not reset the active 3-D ROT.
In row 0 the control always saves the preset that
you most recently set manually via the axis keys or
via soft key. If the preset set manually is active, the
control displays the text PR MAN(0) in the status
display.
Manually saving the presets in the preset table
Proceed as follows in order to save presets in the preset table:
Select the Manual operation mode
Move the tool slowly until it touches (scratches)
the workpiece surface, or position the measuring
dial correspondingly
Press the PRESET MANAGEMENT soft key
The control opens the preset table and sets the
cursor to the row of the active preset.
Press the CHANGE PRESET soft key
The control displays all available input options in
the soft-key row.
Select the row in the preset table that you
want to change (the row number is the preset
number)
If needed, select the column in the preset table
that you want to change
Use the soft keys to select one of the available
entry possibilities