EasyManua.ls Logo

HEIDENHAIN TNC 320 - 16.11 Setting up data interfaces; Serial interfaces on the TNC 320; Application; Setting the RS-232 interface

HEIDENHAIN TNC 320
724 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MOD Functions | Setting up data interfaces
16
HEIDENHAIN | TNC 320 | ISO Programming User's Manual | 10/2017
637
16.11 Setting up data interfaces
Serial interfaces on the TNC 320
The TNC 320 automatically uses the LSV2 transmission protocol
for serial data transfer. The LSV2 protocol is prescribed and cannot
be modified apart from setting the baud rate (machine parameter
baudRateLsv2, no. 106606). You can also define another type of
data transfer (interface). The settings described below are therefore
effective only for the respective newly defined interface.
Application
To set up a data interface, press the MOD key. Enter the code
number 123. In the CfgSerialInterface (no. 106700) machine
parameter, you can enter the following settings:
Setting the RS-232 interface
Open the RS232 folder. The control then displays the following
settings:
Set BAUD RATE
(baud rate no. 106701)
You can set the BAUD RATE (data transfer speed) from 110 to 115
200 baud.