MOD Functions | Select the position display
16
634
HEIDENHAIN | TNC 320 | ISO Programming User's Manual | 10/2017
Display Function
REFDST Distance remaining to the programmed position
in the machine coordinate system; difference
between actual and target positions
Examples with Cycle 11
Scaling factor 0.2
L IX+10
The REFDST display shows 2 mm.
The scaling factor has an effect on the
distance and thus on the display.
M118 Traverse paths that were executed with
handwheel superimpositioning function (M118)
With the MOD function Position display 1, you can select the
position display in the status display.
With the MOD function Position display 2, you can select the
position display in the additional status display.