Tables and Overviews | Functions of the TNC 320 and the iTNC 530 compared
17
688
HEIDENHAIN | TNC 320 | ISO Programming User's Manual | 10/2017
Function TNC 320 iTNC 530
Q parameter programming:
Standard mathematical functions X X
Formula entry X X
String processing X X
Local Q parameters QL
X X
Nonvolatile Q parameters QR
X X
Changing parameters during program interruption X X
D15: PRINT – X
D25: PRESET – X
D26: TABOPEN X X
D27: TABWRITE X X
D28: TABREAD X X
D29: PLC LIST X –
D31: RANGE SELECT – X
D32: PLC PRESET – X
D37: EXPORT X –
D38: SEND X X
Save a file externally with D16
X X
D16 formatting: Left-aligned, right-aligned, string
lengths
X X
Write to LOG file with D16
X –
Displaying parameter contents in the additional status
display
X –
Displaying parameter contents during programming
(Q-INFO)
X X
SQL functions for writing and reading tables