Tables and Overviews | Functions of the TNC 320 and the iTNC 530 compared
17
HEIDENHAIN | TNC 320 | ISO Programming User's Manual | 10/2017
701
Function TNC 320 iTNC 530
Datum table:
Sorting function by values within
an axis
Available Not available
Resetting the table Available Not available
Hiding axes that are not present Available Available
Switching the list/form view Switch via the screen layout key Switchover by toggle soft key
Inserting individual line Allowed everywhere,
renumbering possible after
request. Empty line is inserted,
must be filled with zeros
manually
Only allowed at the end of the
table. Line with value 0 in all
columns is inserted
Transfer of actual position values
on individual axis to the datum
table using the keys
Not available Available
Transfer of actual position values
on all active axes to the datum
table using the keys
Not available Available
Capturing the last positions
measured by TS using the keys
Not available Available
FK free contour programming:
Programming of parallel axes With X/Y coordinates,
independent of machine type;
switchover with FUNCTION
PARAXMODE
Machine-dependent with the
existing parallel axes
Automatic correction of relative
references
Relative references in contour
subprograms are not corrected
automatically
All relative references are
corrected automatically
Q-parameter programming:
Q-parameter formula with SGN Q12 = SGN Q50
if Q 50 = 0 then Q12 = 0
if Q50 > 0 then Q12 = 1
if Q50 < 0 then Q12 = -1
Q12 = SGN Q50
if Q50 >= 0 then Q12 = 1
if Q50 < 0 then Q12 = -1