EasyManua.ls Logo

Heras HMD230+IGD - 3.2 SAFETY DURING USE; 4 INSTALLATION

Heras HMD230+IGD
106 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.heras.com
English
13
3.2 SAFETY DURING INSTALLATION, DISASSEMBLY, USE AND MAINTENANCE
When work is carried out on the gate, the power supply to the system must be switched off
and it must be ensured that it cannot be switched on unexpectedly.
Interrupt the power supply while cleaning the gate.
Use the necessary personal safety equipment.
Keep a safe distance from the moving gate. Warning icons to this effect have
been installed in various locations.
The gate has safety facilities such as anti-crushing safety protection devices.
The anti-crushing safety protection devices serve as emergency facilities to immediately stop
and reverse the gate movement. Using them as a regular gate stop feature is not allowed.
Since the head stiles of the gate have anti-crushing safety protection devices that cannot
cover their full height, there is still some risk of people getting trapped by the gate here.
The gate is driven by means of a gear wheel. This is located under the beam and it
is partly screened off by the drive unit cabinet. Beware of moving parts when
carrying out maintenance under the gate at the drive unit cabinet.
To move the gate manually, first switch the automatic fuse in the drive unit cabinet to “off”
and make sure it cannot be switched on again (e.g. by locking the cabinet).
Always lock the drive unit cabinet during use. The drive unit cabinet may only be opened by
an electrical engineer.
The EN 13241-1, EN 12453 and EN 12445 standards must be taken into consideration during
installation. To achieve a good safety level, both the above standards and the national
regulations must be taken into account in non-EC countries.
The Delta, uGate and iGate have highly tensioned cables fitted in the bottom rail. If these
cables are damaged, they can snap with great force. This can lead to serious injury.
Therefore, it is prohibited to drill into or grind these rails.
!! Only people trained by Heras are allowed to disassemble the
bottom rail.
If the gate is damaged, always contact the supplier for an inspection.
4 INSTALLATION
The sliding gate and the gate drive and control unit must be installed, connected, set up and tuned by
a fitter or an engineer who also connects and programs any accessories.
The gate control unit is adjusted to the options/accessories agreed with the user. The relevant options
are laid down during hand-over.
Of course, you can add optional/accessories afterwards. Contact your supplier for this.
Gates are always delivered fully tested.

Table of Contents