  • R
    Ronald RoachSep 8, 2025
    What does error -7- mean on my Hettich Laboratory Equipment?
    • I
      ihillSep 8, 2025
      Error -7- on your Hettich Laboratory Equipment indicates overspeed, meaning there's an error in the power section. Perform a MAINS RESET to attempt to resolve this.
  • D
    David GarciaSep 7, 2025
    What does error -5- mean on my Hettich ROTOFIX 32 A?
    • T
      Tommy PerkinsSep 7, 2025
      Error -5- on your Hettich Laboratory Equipment indicates an overload, meaning the motor or motor control is defective. To attempt a fix, perform a MAINS RESET.
  • D
    Darlene MilesAug 22, 2025
    What to do if Hettich Laboratory Equipment shows error '-3-'?
    • S
      sbryantAug 22, 2025
      If your Hettich Laboratory Equipment displays error '-3-', it indicates an imbalance, likely due to uneven rotor loading. To resolve this, open the lid, check how the rotor is loaded, and then repeat the centrifugation run.
  • B
    Benjamin MejiaSep 4, 2025
    What does error -8- mean on my Hettich Laboratory Equipment?
    • O
      oharrisSep 4, 2025
      Error -8- on your Hettich Laboratory Equipment indicates undervoltage, meaning the mains voltage is outside the tolerances. Try performing a MAINS RESET and check the mains voltage.
  • A
    Alisha AlexanderSep 3, 2025
    What does error -6- mean on my Hettich ROTOFIX 32 A?
    • A
      arthur71Sep 3, 2025
      Error -6- on your Hettich Laboratory Equipment signifies overvoltage, meaning the mains voltage is outside of the acceptable range. Try performing a MAINS RESET and check the mains voltage.
  • O
    oorrSep 1, 2025
    What to do if Hettich ROTOFIX 32 A displays error -2-?
    • J
      Jeremy GutierrezSep 1, 2025
      Error -2- on your Hettich Laboratory Equipment indicates a loss of mains power during the centrifugation run, meaning the run was not completed. To resolve this, open the lid and press the [START] button. If necessary, repeat the centrifugation run.
  • P
    Patrick MasseyAug 31, 2025
    What does error -3- mean on my Hettich ROTOFIX 32 A?
    • S
      Steve GrayAug 31, 2025
      Error -3- on your Hettich Laboratory Equipment indicates an imbalance, meaning the rotor is unevenly loaded. To resolve this, open the lid, check the rotor loading, and then repeat the centrifugation run.
  • J
    Jim WilsonAug 30, 2025
    What to do if my Hettich Laboratory Equipment shows no display?
    • D
      Darius KleinAug 30, 2025
      If your Hettich Laboratory Equipment's display is blank, it could be due to a lack of power or defective mains input fuses. First, check the supply voltage and the mains input fuse. Then, ensure the mains switch is set to [I].
  • C
    Christopher SalasAug 28, 2025
    Why Hettich ROTOFIX 32 A shows error '-1-'?
    • P
      Patrick SantosAug 29, 2025
      If your Hettich Laboratory Equipment displays error '-1-', it indicates a tacho error, meaning a speed pulse failure. Ensure that the device is not switched off while the ‘Rotation’ indicator is lit up and rotating. Wait until the ‘Lid closed’ symbol is displayed (after approximately 100 seconds) and then perform a MAINS RESET.
  • A
    allen28Aug 27, 2025
    What to do if Hettich ROTOFIX 32 A Laboratory Equipment displays error '-5-'?
    • D
      Donald OdomAug 27, 2025
      If your Hettich Laboratory Equipment shows error '-5-', it indicates an overload, possibly due to a defective motor or motor control. Try performing a MAINS RESET to address this issue.

Summary

Safety

Intended Use of Centrifuge

Defines the centrifuge's intended purpose and application.

User Personnel Requirements

Details user qualifications and requirements.

General Safety Instructions

Provides critical safety warnings and procedures.

Centrifuge Commissioning

Setup and Connection

Guide to setting up and connecting the centrifuge.

Centrifuge Operation

Powering On and Off

Procedure for powering the centrifuge on/off.

Rotor Installation and Removal

Guide for safe rotor removal and installation.

Loading the Centrifuge

Guidelines for loading centrifuge tubes into rotors/buckets.

Centrifugation Procedures

Procedures for performing centrifugation runs.

Software Operation

Setting Centrifugation Parameters

How to set and adjust centrifugation parameters.

Cleaning and Care

Cleaning and Disinfection

Detailed instructions for cleaning and disinfecting the device.

Routine Maintenance

Procedures for routine maintenance.

Troubleshooting Guide

Fault Description and Remedies

Table of common faults, causes, and remedies.

Performing a MAINS RESET

Steps to perform a main power reset.