EasyManuals Logo

Hidea F40 User Manual

Hidea F40
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #97 background imageLoading...
Page #97 background image
91
Trouble Recovery
Water separator-alert indicator
blinks
while cruising
WARNING
Gasoline is highly flammable, and its va-
pors are flammable and explosive.
Do not perform this procedure on a hot
or running engine. Allow the engine to
cool.
There will be fuel in the fuel filter. Keep
away from sparks, cigarettes, flames or
1
1. Plastic
tie
other sources of ignition.
This procedure will allow some fuel to
spill. Catch fuel in a rag. Wipe up any
spilled fuel immediately.
The fuel filter must be reassembled
carefully with the O-ring, filter cup, and
hoses in place. Improper assembly or
replacement could result in a fuel leak,
which could result in a fire or explosion
hazard.
If the water separator-alert indicator on the
Command Link tachometer blinks, perform
the following procedure.
1. Water separator-alert indicator
4. Disconnect the water detection switch
coupler. NOTICE: Be careful not to get any
water on the water detection switch
coupler, otherwise a malfunction could
occur.
1
1. Water detection switch coupler
5. Unscrew the filter cup from the filter
housing. NOTICE: Be careful not to twist
the water detection switch lead when
unscrewing the filter cup.
F40, F60
1. Stop the engine.
2. Remove the top cowling.
3. Remove the plastic tie.