Chapter 6. Parameter Setting
6-8
(2) Output signal display
The output contact status is displayed with either "0" or "1".
Therefore, if the status actually output on the outside is different from the displayed information,
it indicates problem on the input system. As each signal carries different meaning, explanation
is provided through examples below.
(Example of display)
Signal
ALARM3 ALARM2 ALARM1 ALARM TRQOUT RDY ZSPD INSPD/
INPOS
BRK
Display
0 0 0 1 0 1 0 1 1
1: Output signal operating
0: Output signal not operating
Signal Display Description
ALARM 3 0
ALARM 2 0
ALARM 1 0
No Alarm Code
Normal status
ALARM 1 No Alarm, normal status
TRQOUT 0 Torque not limited
RDY 1 No Alarm, Power Good, Servo Ready
ZSPD 0 Motor not stopped
INSPD/INPOS 1 Command speed or command position reached
BRK 1 Motor brake reset signal displayed