6. Troubleshooting and check 
 
6-5 
 
 
[Servo drive overload characteristics curve] 
 
 
(note1) If Ano-03 (OVER LOAD) happens often, refer servo drive overload characteristic-  
              curve and re-establish suitable load of servo motor. 
(note2) The overload alarm occurs 25% faster when the motor is in the Stall state. 
 
 
 
6.2.  Precautions 
 
 - When measuring motor voltage: The voltage output from the servo amplifier to the motor is   
 PWM controlled, so the waveform of pulse phase is output. Since the indicated value can   
 vary greatly depending on the type of instrument, be sure to use a rectified voltmeter for   
 accurate measurements. 
 
 - When measuring the motor current: The pulse waveform is smoothed to a certain sine wave   
 by the reactance of the motor, so connect the moving iron type ammeter directly.