3. Parameter setting   
 
3-26 
 
Speed/Torque/ 
Position control 
  When the servo motor rotates below 10 rpm or in the stall state, it activates the alarm function   
  of overload, over current and over temperature. And the alarm can be cleared only after the set   
  cooling time (P03-25) has elapsed from the alarm occurrence time. 
  If you enter P03-25 = 0 [ms], the alarm function for the stall status is deactivated.   
  * Alarm code: Overload Ano-19, Overcurrent Ano-20, Overtemperature Ano-21   
  * If the corresponding alarm occurs, check the restraint state of the servomotor by   
 checking the machine. 
 
 
3.5.  Input contact point digital speed and torque setting[P04-] 
 
Speed 1 
Digital input speed 1 
Setting range 
-9999.9 ~ 9999.9 
Manufactured 
default 
10.0 
Speed 2 
Digital input speed 2 
Setting range 
-9999.9 ~ 9999.9 
Manufactured 
default 
100.0 
Speed 3 
Digital input speed 3 
Setting range 
-9999.9 ~ 9999.9 
Manufactured 
default 
200.0 
Speed 4 
Digital input speed 4 
Setting range 
-9999.9 ~ 9999.9 
Manufactured 
default 
500.0 
Speed 5 
Digital input speed 5 
Setting range 
-9999.9 ~ 9999.9 
Manufactured 
default 
1000.0 
Speed 6 
Digital input speed 6 
Setting range 
-9999.9 ~ 9999.9 
Manufactured 
default 
2000.0 
Speed 7 
Digital input speed 7 
Setting range 
-9999.9 ~ 9999.9 
Manufactured 
default 
3000.0 
Torque 1 
Digital input torque 1 
Setting range 
-300.0 ~ 300.0 
Torque 2 
Digital input torque 2 
Setting range 
-300.0 ~ 300.0 
Torque 3 
Digital input torque 3 
Setting range 
-300.0 ~ 300.0 
Manufactured 
default 
20.0 
Torque 4 
Digital input torque 4 
Setting range 
-300.0 ~ 300.0 
Manufactured 
default 
50.0