2. Wiring and connection 
2.1.1.  Connection of AC220V Series 
RS232/485
It sets various parameters and 
displays the operating status.
GND
3-Phase 
AC200 ~ 230V
50 ~ 60Hz
R S T
N F B
NOISE FILTER
Power specification : Use the power specification 
3-phase within AC200~230V permitted by the servo 
for use. For the power voltage of AC400V level, 
always use the power transformer.
NFB (No Fuse Circuit Breaker) : It breaks the circuit 
when over-current flows and is used for power line 
maintenance.
Noise filter : You must use this to blocks the 
external noise inflowing in the commercial power.
CN1 : This is the connector to 
connect the servo drive to the higer 
device. You can connect to the 
higher device including PLC, NC, 
Motion controller etc.
Wiring : Mis-wiring can damage the servo driver. 
The control signal line must be sufficiently away 
form the main circuit wiring and it is very important 
not to be affected by the noise.
Magnetic contactor : It turns on/off the 
servo power. Do not start or stop the 
servo with this magnetic contactor. It can 
reduce the life of the servo.
Motor power wiring : The U, V, W 
and F.G. terminal of the drive and 
motor must be aligned. 
Motor : Do not apply impact to the 
shaft and detector of the motor with a 
hammer etc.
Encoder wiring : Connect the connector of the 
encoder cable.
Grounding : To prevent electric 
shock, the terminal of motor and 
drive must be grounded in type 3 
or above grounding to the closest 
point.
Servo drive : The life of the servo is 
affected by the surrounding 
temperature. Set the ambient 
temperature to below 50
an average of 40.
CN2
CN1
U V W
FG
R
S
T
r
t
Magnetic 
Contactor
Internal regenerated 
resistor
CN3
DC power : When main 
power is DC voltage, supply 
DC 280 ~ 325 [V] between 
P[+] and N[-].  
terminal.