6. Troubleshooting and check 
 
6-1 
 
6.1.  Troubleshooting 
 
6.1.1.  Servo motor 
 
Check the parameter of 
motor, encoder, encoder 
type, control mode etc. 
Reset parameter. 
(Refer to Chapter 3) 
Check the revolution 
condition of the machine. 
Readjust the machine device. 
Measure the motor lead 
terminal with a tester. 
For normal voltage, replace the 
motor. 
Check the connection part 
with drive. 
External mis-wiring 
Cable disconnection 
Check motor and encoder 
wiring. 
Rework on the wiring. 
Replace the cable. 
Check the output wave 
shape. 
Replace the encoder. 
(Request for repair) 
Motor 
revolution 
is unstable 
Wiring connection 
defectiveness 
Check the connection of 
the motor lead terminal. 
Check the drive input 
voltage. 
Check the machine 
condition. 
Remove any particle on the 
revolution part and supply 
lubricant (or grease) 
Check the surrounding 
temperature of the motor 
installation part. 
(40  or below) 
Reduce ambient temperature to 
40  max. 
Contamination on 
motor surface 
Check whether there are 
any alien particles on the 
motor surface. 
Check the load rate of the 
drive. Check the 
acceleration/deceleration 
frequency. 
Reduce load. Increase 
acceleration/deceleration time. 
Low magnetic power 
of magnet 
Check the comparator 
voltage and voltage wave 
shape.