5. Servo operating 
 
4-23 
 
4.6.  Precaution for absolute encoder 
 
  In the host controller, when detecting the absolute position of the machine even when the power 
of  the  servo  drive is  turned  off,  you  must  use  an  absolute  type  servo motor  and  drive.  If  you 
connect the power to the absolute type servo system, you can make a machine system that can 
directly  enable auto  operation with additional  position detection operation without the difference 
between the absolute type drive and standard type drive is whether there is a back-up battery.   
 
4.6.1.  Battery handling 
   
  The  battery  supplies  the  back-up  power  to  store  the  position  information  of  the  “Absolute 
encoder” even when the drive power is turned off. 
 
1)  Recommended battery specification 
 
Connecting the battery to the host controller 
Connecting the battery to the servo drive 
Lithium battery Tekcell SB-AA0 type 
3.6V 2400mAh 
 
1. Connector attached type   
2. Main unit: Lithium battery Tekcell SB-AA0   
type 3.6V 2400mAh 
 (Connect to CN5 of servo drive) 
 
  2) Battery connection 
- FDA7001~7045, FDA7004B~7030B, FDA7002EX~7045EX   
 : Attached to the inside of the servo drive 
 
 
 <a> : Open the cover and insert the battery unit in the arrow direction.   
<b> : Connect the connector to CN5.