2. Wiring and connection 
 
2-20 
 
(Note3) In case of FDA7004 ~ FDA7010 model, regenerative resistor is installed inside servo   
 drive. In case of For FDA7015-7150 and FDA7020-H~7750-H, the regenerative resistor   
 must be installed externally. In case of FDA7075 ~ 7150, FDA7075-H ~ 7750-H, please   
 contact our sales office because regenerative resistance is sold separately. 
(Note4) Be sure to ground the ground wire of CN1 cable to FG (Frame Ground) terminal. 
(Note5) This is the wiring when position command pulse is connected by line drive method. 
(Note6) This is the wiring when connecting position command pulse with open collector method. 
(Note7) This is the wiring when connecting Z phase pulse with line drive method.. 
(Note8) This is the wiring method when connecting Z phase pulse with open collector method. 
(Note9) GND24 (CN1-24, 25) and GND (CN1-1, 8, 26, 33, 34, 36) must be connected   
 separately. If two grounds are connected in common, the servo drive may malfunction or   
 break down. 
 
 
2.5.3.  Input signal function table (manufactured default) 
 
Function and usage explanation 
It  decides  whether  the  servo  motor  can  be  operated  or 
not. (ON: Enable    OFF: not Enable) 
Speed selection 1/ 
Electronic gear 
selection 1/ 
-  Internal  command  speed  selection  by  3  signal  (SPD1, 
SPD2, SPD3) combination Speed control 
 
 
-  Electronic  gear  ratio  selection  by  2  signal  (GEAR1, 
GEAR2) combination Position control 
Speed selection 2/ 
Electronic gear 
selection 2/ 
Selects the Speed/Position/Torque input direction.   
(OFF: Positive direction selected    ON: Negative direction 
selected) 
CCW limit / 
Positive torque limit 
Limit signal input on CCW (Speed control)/ 
Positive torque generation prohibited (Torque control) 
  (ON: Cancel OFF: Prohibited) 
CW limit / 
Negative torque limit 
Limit signal input on CW (Speed control)/ 
Negative torque generation prohibited (Torque control) 
  (ON: Cancel OFF: Prohibited) 
Speed limit / 
Torque limit 
Speed limit use input contact point (Torque control)/ 
Selects  whether  to  use  torque  limit  (Analog  torque  input 
and  digital  torque  input  can  be  used  according  to  the 
combination of TRQ1, TRQ2 and TRQ3 Speed control.) 
This cancels the alarm condition.