1. Model check and handling 
1-3 
1.2.3.  Common specifications. 
 
  17/33bit Serial encoder, 11/13bit Absolute encoder,   
Incremental 2000 ~ 6000 [ppr] (15line), 8192 [ppr] (9line) 
  Serial communication, Differential Line Driver 
  Maximum of 131072 [pulse] per 1 encoder revolution 
  Sine wave PWM control ( using by IPM ) 
Speed 
control 
specification 
  Internal speed command 1:5000, analog speed command 1:2000 
  Analog Speed Command : DC -10 ~ +10 [V] 
  Digital Speed Command with combination SPD1 ~ SPD3 
  ± 0.01 % or below (rated load condition : 0 ~ 100 % ) 
  ± 0.01 % or below (rated voltage condition : ± 10 %) 
  ± 0.1 % or below (temperature fluctuation condition: 25 ± 25 C ) 
  Acceleration/ 
  Deceleration time 
  Straight, S-curve ( 0 ~ 100 [sec] ) 
Position 
control 
specification 
  Line drive type : 500 [kpps], open collector type : 250 [kpps] 
  Direction + pulse, Forward pulse + reverse pulse 
  2 phase pulse (A phase + B phase ) 
  Open Collector, Line Driver 
Torque 
control 
specification 
  Analog torque Command : DC -10 ~ +10 [V] 
  Digital torque Command with combination TRQ1 ~ TRQ3 
  Analog Speed limit Command : DC -10 ~ +10 [V] 
  Digital Speed limit Command with combination SPD1 ~ SPD3 
  Over current,  over voltage, over temperature,  over speed,  motor  miss 
wiring,   
  encoder problem, insufficient voltage, follow error, CCW/CW limit, IPM 
fault, 
  memory problem, emergency stop etc.   
  Command/current position, speed, torque ( -5 ~ +5 [V] ) 
  Key JOG, 8 pattern Auto JOG alarm history, rotation direction, encoder   
  signal  division  pulse  out,  auto-tuning,  2-notch  filter,  speed  ripple 
suppress   
  etc. 
  Motor power cable, encoder cable, CN1 cable 
  RS232/485 COM cable, absolute encoder battery pack, P-dori ,   
  user manual 
Environ-
mental 
specification 
  90[] or below (no condensation) 
  DC 500[V] 10 [M] or more