Figure 16-6 SNMP Settings
Step 2 Check Enable. A message will pop up to prompt possible security risk and click Yes to continue.
Step 3 Configure the SNMP settings as needed.
Trap Address: IP address of the SNMP host.
Trap Port: Port of the SNMP host.
Step 4 Click Apply.
16.7 Configure Email
Purpose
The system can be configured to send an Email notification to all designated users when a specified
event occur, such as an alarm or motion event is detected, or the administrator password is
changed, etc.
Before You Start
The device must be connected to a local area network (LAN) that contains an SMTP mail server.
The network must also be connected to either an intranet or the Internet depending on the
location of the e-mail accounts to which you want to send notification.