Video Security Control Panel User Manual
Parameters Initialization
Q: What are the steps of LED keypad to program the control panel?
A:
1. In overall keypad programming mode, the program command is: {installer password} + {*} + {0} + {#};
2. To view the configuring operation for security control panel, please refer to alarm keypad configuring
code;
For example: program user password 2#, the password has arm/disarm function, does not send arming
report, does not allow bypass, password is 5678, and the program code is shown as follow:
Command Code Arming Type Password End
{0}{0}{2} {3} {5}{6}{7}{8} {#}
3. Set program command
There are 2 alert sound of correct or 5 alert sound of error and corresponding OSD notices after each
program command is over. When 5 alert sound of error is heard and the screen displays Operation
Failed, there is error in program command setting and the user need to reset correct program
command. When 2 alert sound of correct is heard and the screen displays Operation Succeeded but
the setting parameters are not the parameters needed, you can operate according to program
command once again.
4. Exit program mode, the program command is: {*} + {#}.
Q: What is the meaning of LED keypad Arm/Disarm, Operate, Camera indicators?
A:
LED alarm keypad Arm/Disarm indicator:
Main Operator Change
Password
LED alarm keypad Operate indicator: