16.2 Troubleshooting
No image displayed on the monitor after starting up normally.
Possible Reasons
a) No HDMI
TM
connections.
b) Connection cable is damaged.
c) Input mode of the monitor is incorrect.
Steps
1. Verify the device is connected with the monitor via HDMI
TM
cable.
If not, please connect the device with the monitor and reboot.
2. Verify the connection cable is good.
If there is still no image display on the monitor after rebooting, please check if the connection cable is
good, and change a cable to connect again.
3. Verify Input mode of the monitor is correct.
Please check the input mode of the monitor matches with the output mode of the device (e.g. if the
output mode of NVR is HDMI
TM
output, then the input mode of monitor must be the HDMI
TM
input).
And if not, please modify the input mode of monitor.
4. Check if the fault is solved by the step 1 to step 3.
If it is solved, finish the process.
If not, please contact the engineer from our company to do the further process.
There is an audible warning sound “Di-Di-Di-DiDi” after a new bought NVR starts up.
Possible Reasons
a) The installed HDD has not been initialized.
b) The installed HDD is not compatible with the NVR or is broken-down.
Steps
1. Verify the HDD is initialized.
1) Select “Menu > HDD > General”.
2) If the status of the HDD is “Uninitialized”, please check the checkbox of corresponding HDD and
click the “Init” button.
2. Verify the HDD is detected or is in good condition.
1) Select “Menu > HDD > General”.
2) If the HDD is not detected or the status is “Abnormal”, please replace the dedicated HDD according
to the requirement.
3. Check if the fault is solved by the step 1 to step 2.
If it is solved, finish the process.
If not, please contact the engineer from our company to do the further process.
The status of the added IP camera displays as “Disconnected” when it is connected through Private
Protocol. Select “Menu > Camera > Camera” to get the camera status.
Possible Reasons
a) Network failure, and the NVR and IP camera lost connections.
b) The configured parameters are incorrect when adding the IP camera.
c) Insufficient bandwidth.
Steps
1. Verify the network is connected.
1) Connect the NVR and PC with the RS-232 cable.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-7108NI and is the answer not in the manual?

HIKVISION DS-7108NI Specifications

General IconGeneral
ModelDS-7108NI
Channels8
HDD Bays1
Recording Resolution8 MP/6 MP/5 MP/4 MP/3 MP/1080p/UXGA/720p/VGA/4CIF/DCIF/2CIF/CIF/QCIF
SATA1 SATA interface
Operating Humidity10% to 90%
TypeNetwork Video Recorder
Max HDD Capacity6TB
Video Output1 × VGA, 1 × HDMI
HDMI Output Resolution1920 × 1080/60Hz, 1280 × 1024/60Hz, 1280 × 720/60Hz, 1024 × 768/60Hz
VGA Output Resolution1920 × 1080/60Hz, 1280 × 1024/60Hz, 1280 × 720/60Hz, 1024 × 768/60Hz
Audio Input1-channel RCA
Audio Output1-channel RCA
Decoding FormatH.264
Resolution8MP
Capability8-ch @1080p
Network Interface1 RJ45 10M/100M self-adaptive Ethernet interface
USB Interface2 USB 2.0
Operating Temperature-10 °C to +55 °C (+14 °F to +131 °F)