Peripheral Devices
7.1 Using a PC Card
109
: Possible/ × : Not Possible
Peripheral Devices 7
7.1 Using a PC Card
File and File Format
Directory
Name
File Name
SYSTEM_DF4
[
PC-CARD]
Files
can be
opened
on a PC
Using
with the
9624/
9624-10
SAVE LOAD
Setting Files ____________
########.SET
●● ×
B+Date+No.*8
3196SET.SET
●● ×
Measure-
ment Data
Files
Binary
format
Time-series data*4
96INTVL.ITV
●● ×
Event data*1, *3 96EVT000.EVT to
96EVT999.EVT
●● ×
Transient waveform
data *1
00000000.TRN to
99999999.TRN
●● ×
V10/ IEC Flicker
data *1
96FLICK.FLC
●● ×
Voltage fluctuation
event data *3,*7
96DV000.WDU to
96DV999.WDU
●● ×
Text
format
Time-series data*1 T+Date+No.*8
96INTVL.CSV
× ×
Event list data *1, *5
96EVENT.TXT
× ×
V10/ IEC Flicker
data*1
96FLICK.TXT
× ×
Voltage fluctuation
event data *3,*7
HHMM000.CSV to
HHMM999.CSV
× ×
Event waveform
data *2, *6
TEXTWAVE
HHMM000.CSV to
HHMM999.CSV *9
*10
× ×
Screen Hard Copy Files ____________ H3196000.BMP to
H3196999.BMP
× ×
Storage method
*1: Files can be saved automatically every interval, or saved manually after measurement is fin-
ished (when analyzing).
*2: After measurement is finished (when analyzing), you can select an event number and save files
manually.
*3: Data is saved automatically each time an event occurs.
Creating event files
*4: A file is created for each event (event data for all of the contents, including waveforms).
*5: All of the events in the list are created within a single file.
*6: A file is created for each event waveform.
*7: A file is created for each voltage fluctuation event graph.
Creating a directory and file name
*8: A number is appended to files each time measurement data is saved.
Binary format: B/ Text format:T(1-digit)+Date(5-digit: year,month,day) + Number(2-digit:01 to 99)
The year is indicated using the lowest digit. (Example: The year 2002 is represented as “2”.)
3196SET.SET is also saved in the text format directory.
*9: HH indicates hours, and MM indicates minutes.
*10:EVENT_DF1[LIST] is used to save event waveform data in text format.
Card type: Flash ATA Types I and II
Slot: One Type II
Format: MS-DOS
Storage capacity: Up to 528 MB
The PC Card interface of this instrument complies with
PCMCIA (Personal Computer Memory Card Internation
-
al Association) and JEIDA (Japan Electric Industry De
-
velopment Association) PC Card standards.

Table of Contents