9.3 Troubleshooting
94
The [REC] indicator disap-
pears even though record-
ing has not been stopped.
The one-time recording stop
method is selected.
With one-time recording, recording
stops automatically when memory
becomes full. Change the stop meth-
od to endless recording.
See: Making Settings on the Log-
ger:"Stop Method Setting (for
when memory becomes full)"
(p.30)
See: Making Settings from the
LR5000 Utility Program:"Stop
Method" (p.35)
(With endless recording, the oldest
data is overwritten when memory is
full, so be sure to save data to a com-
puter periodically during long-term re-
cording. Data can be saved to a
computer without stopping record-
ing.)
See: "4.5 Automatically Importing
(Saving) Recorded Data to a
Computer, and Graph Display"
(p.45)
The logger cannot commu-
nicate with the new LR5091
(LR5092).
The installation of the device
driver to the LR5091 (LR5092)
failed.
For Window XP, the driver may be re-
quired to be installed to each LR5091
(LR5092).
Open Windows Device Manager and
re-install the driver.
Before requesting repairs
Problem Symptom Probable Causes Remedies and References