Error Code
Error
Cause
Elimination
E16
Fallen below lower
limit value in
measuring channel
"angle 2"
Angle potentiometer
defective
Replace angle sensor
Electronic component in
the measuring channel
defective.
Replace sensor unit
E17
Fallen below lower
limit value "length
telescope I (+II)"
Length potentiometer
defective
Replace length sensor.
Electronic component in
the measuring channel
defective
Replace sensor unit
E18
Front outrigger
overloaded
Front outrigger
overloaded
E1A
Fallen below lower
limit value in
measuring channel
"slewing angle 1".
Cable between the
central unit and the
slewing angle sensor
defective or loose. Water
inside the plug of the
angle sensor
Check cable as well as
plugs, replace, if need be.
Slewing angle
potentiometer is defective
Replace slewing angle
sensor
Electronic component in
the measuring channel
defective
Replace sensor unit
E1B
Fallen below lower
limit value in
measuring channel
"slewing angle 2"
refer to E1A
refer to E1A
E1C
Fallen below lower
limit value in
measuring channel
"luffing jib angle"
Angle potentiometer
defective
Replace angle sensor
Electronic component in
the measuring channel
defective.
Replace sensor unit