Service Manual iFLEX5
© Hirschmann Rev. I 0522/17 190154_I.DOC
66
Error Code
Error
Cause
Elimination
E31
Error in the system
program
The system program file
is defective.
Flash-EPROM defective
Upload valid system
software
Replace central unit
E37
Error in the logical
program flow
System program file is
defective
Flash-EPROM defective
Upload valid system
software
Replace central unit
E38
System program
and crane data file
do not match.
The system program in
the LMI does not match
to the programming in the
crane data file
Upload valid system
program file or the valid
crane data file
E39
System program
and load chart file
do not match
The system program in
the LMI and the
programming in the load
chart file do not match.
Upload valid system
program file or the valid
load chart file
E43
Error in the
write/read memory,
(RAM)
Write/read memory
(RAM) or central unit
defective.
Replace central unit
E47
Error in the
monitored write/
read memory.
The CRC
verification of the
monitored
write/read memory
provides an
incoherent result
The CRC sign of the
monitored write/read
memory is wrong
The buffer battery is
decharged (< 2V at
1kOhm).
Central unit defective.
Restart the LMI
Replace buffer battery on
the central unit.
Replace central unit
E51
Error in the crane
data file
No valid data in the crane
data file.
Flash-EPROM defective
Upload valid crane data
file
Replace central unit
E52
Error in load chart
file.
No valid data in the load
chart file
Flash-EPROM defective
Upload valid load chart
file
Replace central unit
E56
Error in crane data
file.
No valid data in the crane
data file during
calibration.
Flash-EPROM defective
Restore or upload valid
crane data file
Replace central unit
E57
Error in serial crane
data file.
Calibration data file does
not contain valid data.
Flash-EPROM defective
Upload calibration data
file
Replace central unit